Menu
Your Cart

PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply

PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
PLANET PWR-960-48 960W 48V DC Single Output Industrial DIN-rail Power Supply
  • Stock: In Stock
  • Brand: PLANET
  • Model: PWR-960-48
  • Weight: 2.64kg
  • Dimensions: 12.50cm x 3.20cm x 10.20cm
650.18€
Ex Tax: 524.34€

Compact Size with more Practicability and Convenience 

PLANET has released a series of DC single output industrial DIN-rail power supply units to make sure that industrial Ethernet devices, specially designed for the harsh working environment, get DC voltage power easily.

PLANET DC single output industrial DIN rail power supply units accept universal 100-240V AC input voltage and provide 48V DC power output with various watt values. Its power supply units are designed in compact size and can be installed on DIN rail TS-35 / 7.5 or 15. It is an ideal and convenient DC power feeding solution for Industrial equipment under heavy Industrial environments.

Stable Performance under Difficult Environments

PLANET DC single output industrial DIN-rail power supply units come with such protection features as short circuit, overload, over voltage and over temperature for the stable operation of industrial Ethernet equipment. It uses the free air convection cooling system to prevent operating temperature from rising. Being able to operate under the temperature range from -30 to 70 degrees C (maximum), the DC single output industrial DIN-rail power supply units can be placed in almost any difficult environments.

Ideal 48V DC Power Feeding Solution for PoE Industrial Equipment

The following DC single output industrial DIN-rail power supply units provide sufficient 48V power to industrial PoE equipment, such as industrial PoE Ethernet switches and industrial PoE wireless access points. The model names and specifications are:

  • PWR-75-48 (MEAN WELL -- NDR-75-48):
    • 75W 48V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)
  • PWR-120-48 (MEAN WELL -- NDR-120-48):
    • 120W 48V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)
  • PWR-240-48 (MEAN WELL -- NDR-240-48):
    • 240W 48V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)
  • PWR-480-48 (MEAN WELL -- NDR-480-48):
    • 480W 48V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)
  • PWR-960-48 (MEAN WELL -- SDR-960-48):
    • 960W 48V DC Single Output Industrial DIN-rail Power Supply (-30 ~ 70 degrees C)

 

PWR-75-48 (MEAN WELL/NDR-75-48)

  • Universal AC input for full operation
  • Protection features: short circuit, overload, over voltage  and over temperature
  • Cooling by free air convection
  • DIN rail TS-35/7.5 or 15 installation
  • UL 508 (industrial control equipment) approved
  • EN61000-6-2 (EN50082-2) industrial immunity level
  • 100% full load burn-in test

 

PWR-120-48 (MEAN WELL/NDR-120-48)

  • Universal AC input for full operation
  • Protection features: short circuit, overload, over voltage  and over temperature
  • Cooling by free air convection
  • DIN rail TS-35/7.5 or 15 installation
  • UL 508 (industrial control equipment) approved
  • EN61000-6-2 (EN50082-2) industrial immunity level
  • 100% full load burn-in test

 

PWR-240-48 (MEAN WELL/NDR-240-48)

  • Universal AC input for full operation
  • Built-in active PFC function
  • Protection features: short circuit, overload, over voltage and over temperature
  • Cooling by free air convection
  • DIN rail TS-35/7.5 or 15 installation
  • UL 508 (industrial control equipment) approved
  • EN61000-6-2 (EN50082-2) industrial immunity level
  • 100% full load burn-in test

 

PWR-480-48 (MEAN WELL/NDR-480-48)

  • Universal AC input full operation
  • Built-in active PFC function
  • Protection features: short circuit, overload, over voltage and over temperature
  • Cooling by free air convection
  • DIN rail TS-35/7.5 or 15 installation
  • UL 508 (industrial control equipment) approved
  • EN61000-6-2 (EN50082-2) industrial immunity level
  • 100% full load burn-in test

 

PWR-960-48 (MEAN WELL/SDR-960-48)

  • Universal AC input full operation
  • Built-in active PFC function
  • Protection features: short circuit, overload, over voltage and over temperature
  • Cooling by free air convection
  • DIN rail TS-35/7.5 or 15 installation
  • UL 508 (industrial control equipment) approved
  • EN61000-6-2 (EN50082-2) industrial immunity level
  • 100% full load burn-in test

 

PWR-75-48 (MEAN WELL/NDR-75-48)
Dimensions (W x H x D)32 x 125 x 102 mm
Weight (kg)0.51kg
Input Voltage90 ~ 264VAC, 50/60Hz
127 ~ 370V DC
[DC input operation possible by connecting AC/L(+), AC/N(-)]
Power Output75 watts,48V, 1.6A
TemperatureOperating:-20~70 degrees C (**)
Storage:-40~85 degrees C
HumidityOperating: 20 ~ 95%
Storage: 10 ~ 95% (non-condensing)
InstallationDIN rail TS-35/7.5 or 15
Safety & FunctionUl508, TUV EN60950-1 approved (meeting EN60204-1)
*Note*The specification is for PWR-75-48 hardware version 1 only.
**Please refer to output load derating curve from product specification.
PWR-120-48 (MEAN WELL/NDR-120-48)
Hardware Version2
Dimensions (W x H x D)40 x 125 x 113 mm
Weight (kg)0.6kg
Input Voltage90 ~ 264VAC, 50/60Hz
127 ~ 370V DC
[DC input operation possible by connecting AC/L(+), AC/N(-)]
Power Output120 watts, 48V, 2.5A
TemperatureOperating:-20~70 degrees C (**)
Storage:-40~85 degrees C
HumidityOperating: 20 ~ 95%
Storage: 10 ~ 95% (non-condensing)
InstallationDIN rail TS-35/7.5 or 15
Safety & FunctionUl508, TUV EN60950-1 approved (meeting EN60204-1)
*Note*The specification is for PWR-120-48 hardware version 2 only.
**Please refer to output load derating curve from product specification.
PWR-240-48 (MEAN WELL/NDR-240-48)
Hardware Version2
Dimensions (W x H x D)63 x 125 x 113 mm
Weight (kg)1kg
Input Voltage90 ~ 264VAC, 50/60Hz
127 ~ 370V DC
Power Output240 watts, 48V, 5A
TemperatureOperating:-20~70 degrees C (**)
Storage:-40~85 degrees C
HumidityOperating: 20 ~ 95%
Storage: 10 ~ 95% (non-condensing)
InstallationDIN rail TS-35/7.5 or 15
Safety & FunctionUl508, TUV EN60950-1 approved (meeting EN60204-1)
*Note*The specification is for PWR-240-48 hardware version 2 only.
**Please refer to output load derating curve from product specification.
PWR-480-48 (MEAN WELL/NDR-480-48)
Hardware Version2
Dimensions (W x H x D)85 x 125 x 128mm
Weight (kg)1.5kg
Input Voltage90 ~ 264VAC, 50/60Hz
127 ~ 370V DC
Power Output480 watts, 48V, 10A
TemperatureOperating:-20~70 degrees C (**)
Storage:-40~85 degrees C
HumidityOperating: 20 ~ 95%
Storage: 10 ~ 95% (non-condensing)
InstallationDIN rail TS-35/7.5 or 15
Safety & FunctionUl508, TUV EN60950-1 approved (meeting EN60204-1)
*Note*The specification is for PWR-480-48 hardware version 2 only.
**Please refer to output load derating curve from product specification.
PWR-960-48 (MEAN WELL/SDR-960-48)
Dimensions (W x H x D)110 x 125 x 150mm
Weight (kg)2.47kg
Input Voltage180 ~ 264VAC, 50/60Hz
254 ~ 370V DC
Power Output960 watts, 48V,20A
TemperatureOperating:-30~70 degrees C (**)
Storage:-40~85 degrees C
HumidityOperating: 20 ~ 95%
Storage: 10 ~ 95% (non-condensing)
InstallationDIN rail TS-35/7.5 or 15
Safety & FunctionUL508, UV BS EN/EN62368-1, BSMI CNS14336-1, AS/NZS62368.1, EAC TP TC 004 approved (meeting EN60204-1)
*Note*The specification is for PWR-960-48 hardware version 1 only.
** Please refer to output load derating curve from product specification.

 

Datasheet

DateVersionDescriptionDownload
2024-04-122.1PWR-120-48/PWR-240-48/PWR-480-48/PWR-75-48/PWR-960-48

 

User's Manual

DateVersionDescriptionDownload
2023-09-011.6Release for PWR-120-48/240-48/PWR-480-48 Version 2.0, add New model PWR-960-48.
2016-09-231.4Release for PWR-120-48/240-48/PWR-480-48 Version 2.0, add New model PWR-75-48.
2013-08-091.3Add PWR-480-48.