Menu
Your Cart

PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)

PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
PLANET ICS-2102T IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100BASE-FX SC, Multimode - 2km)
  • Stock: In Stock
  • Brand: PLANET
  • Model: ICS-2102T
  • Weight: 0.61kg
  • Dimensions: 8.78cm x 3.20cm x 13.50cm
206.21€
Ex Tax: 166.30€

Cost-effective Solution for RS232/422/485 Serial-to-Industrial Ethernet Application

PLANET ICS-210xT Serial Device Server series is specially designed to convert RS232, RS422 or RS485 serial communication to Industrial Fast Ethernet networking so as to extend the network distance efficiently and inexpensively. There is one 100BASE-FX single-mode/multi-mode media available in the ICS-210xT series and its operating temperature ranges from -40 to 75 degrees C for your network needs. The ICS-210xT series is a time-saving and cost-effective solution for users and system integrators to quickly transform their serial devices into the Ethernet network with no need of replacing the existing serial devices and software system.

Efficiently Extend Network Distance

The ICS-210xT series especially equips one fiber interface (100BASE-FX, choice of fiber-connector from SC / LC, multi-mode / single-mode fiber) and is able to extend the distance of deploying serial equipment and hosts. Users are able to select fiber-optic cables (based on distance) provided for distance extension from 2 kilometers (via multi-mode fiber) to 60 kilometers (via single-mode fiber) or longer.

 

Remote Management 

As the ICS-210xT series provides easy serial-to-Ethernet connectivity and connection to a TCP/IP network, the remote network system can thus be managed efficiently via its Web, telnet, and VCOM management interfaces. It supports both application and serial operation modes for alarm or IP address connection, which saves the network administrator’s time in detecting and locating network problems without visual inspection of the cabling and devices. Multiple connection options are available for a large networking environment as well.

Stable Performance under Difficult Environments

The ICS-210xT series provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curbside traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the ICS-210xT series to be placed in almost any difficult environment.

The ICS-210xT series with compact IP30 standard metal case allows either DIN-rail or wall mounting for efficient use of cabinet space. The ICS-210xT series also provides an integrated power supply source with a wide range of voltages (9 to 48V DC/24V AC) ideally suitable for worldwide operation with high availability applications requiring dual or backup power inputs.

Dual Power Input for High Availability Network System

The ICS-210xT series features a strong dual power input system with wide-ranging voltages (9V~48V DC/24V AC) incorporated into customer’s automation network to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically to keep powering the ICS-210xT series via Power Supply 2 without any break of operation.

Effective Alarm Alert for Better Protection

The ICS-210xT series comes with a Fault Alarm feature which can alert the users when there is something wrong with the Serial Device Server. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource. The ICS-210xT series provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.

Access Control System – Traditional System Application

Most of the enterprises and government use access control plate and Mifare or RFID to authorize entrance identity. Traditionally, the access control machines use RS232 or RS485 serial interface with their cables connecting to login server. By applying the ICS-210xT series Serial Device Server, the access control machine is able to extend the network over longer distances via Ethernet interfaces. In addition, the ICS-210xT series can be linked to an xDSL router to get the internet access capability so that the access control can be set and monitored over the internet.

 

Process Control

To monitor, configure and manage the robotic conveyer including other production machines, PLC (Programmable Logical Control) is required to drive the above manufacturing process. The ICS-210xT series can be set to the TCP Server mode and connected to the PLC.  Thus, the administrator can configure and set command settings through Fast Ethernet intranet to remotely control the PLC, without having to stand by the I/O machine.

Surveillance Motion Control – Pair Connection Mode

Using pair connection mode via the fiber optic patch cord, the ICS-210xT series can extend the distance of the deployed devices via RS232, RS422 and RS485 interfaces, making the remote management of these devices from the monitoring center easier and efficient.

Serial Interface

  • One DB9 interface that supports RS232
  • One terminal block interface that supports 2-wire RS485 and 4-wire RS422/RS485 standards
  • Asynchronous serial data rates up to 921600bps
  • Data modes include VCOM, RFC2217, TCP Server, TCP Client, UDP, Remote Pair, Modbus converter server / client and Serial Telnet modes

 

Ethernet Interface

  • Choice of fiber-connector from SC/LC, multi-mode/single mode fiber

 

Management

  • IPv4 and IPv6 dual stack management
  • Remote Management Interfaces
  • - IP-based Web management
    - Telnet console management
    - Windows-based VCOM utility supports searching, monitoring and configuration setting
  • IP NTP (Network Time Protocol) and DNS management
  • Standard TCP/IP interface and versatile operation modes
  • Software Protocol supports ARP, ICMP, TCP/IP, UDP, HTTP server, DHCP client, Telnet server/client 
  • Serial Operation mode selected via management interface
  • Pair Connection mode for connecting two serial devices over a network
  • Allows a maximum of 4 hosts to be accessed as TCP client mode
  • Firmware upgrade via HTTP protocol
  • Accessible IP security control to prevent illegal users
  • Event notification
  • - Remote Syslog server
    - SNMP trap
    - Relay output alarm
  • DHCP client for IP address assignment 
  • PLANET Smart Discovery utility automatically finds the client devices on the network 

 

Industrial Case and Installation

  • IP30 metal case
  • DIN-rail and wall-mount designs
  • Redundant power design
  • - 9 to 48V DC / 24V AC, redundant power with reverse polarity protection
  • Supports 6000 VDC Ethernet ESD protection
  • -40 to 75 degrees C operating temperature
  • Free fall, shock-proof and vibration-proof for industries
  • Supports extensive LED indicators for network diagnosis
  • Reset button for resetting to factory default
Serial Interface
Serial PortsICS-2105AT
1 x DB9 male for RS232
1 x 4-Pin Terminal block for RS422 / RS485

ICS-2102T
1 x DB9 male for RS232
1 x 4-Pin Terminal block for RS422 / RS485

ICS-2102TS
1 x DB9 male for RS232
1 x 4-Pin Terminal block for RS422 / RS485
Serial StandardsRS232 / 4-wire RS422 or RS485 / 2-wire RS485
Baud Rate (Data Rate)50bps to 921Kbps
Data Bits5, 6, 7, 8
Parity Type1, 1.5, 2
Stop BitOdd, Even, None, Space, Mark
Flow ControlRTS/CTS and DTR/DSR (RS232 only)
XON/XOFF
SignalsRS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS422: Tx+, Tx-, Rx+, Rx-, GND
4-wire RS485: Tx+, Tx-, Rx+, Rx-, GND
2-wire RS485: Data A (+), Data B (-), GND
Pin AssignmentSerial Port
PinRS232RS422
RS485-4W
RS485-2W
1DCDTxD+--
2RxDTxD---
3TxDRxD-Data-
4DTRRxD+Data+
5GNDGNDGND
6DSR----
7RTS----
8CTS----
9------


4-pin Terminal Block
PinRS422
RS485-4W
RS485-2W
1TxD+(A)--
2TxD-(B)--
3RxD-(B)Data-(B)
4RxD+(A)Data+(A)
Ethernet Interface
Ethernet PortsICS-2105AT: 1 x SFP
ICS-2102T/ICS-2102TS: 1 x Duplex SC
Standard100BASE-FX
ConnectorICS-2105AT: LC
ICS-2102T/ICS-2102TS: Duplex SC
Fiber ModeICS-2105AT: Single mode or multi-mode (may vary on SFP module)
ICS-2102T: Multi-mode
ICS-2102TS: Single mod
Transmission ModeFull duplex
DistanceICS-2105AT: 2km to 120km (may vary on SFP module)
ICS-2102T: 2km
ICS-2102TS: 30km
CableICS-2105AT:
50 or 62.5/125μm multi-mode fiber cable
9/125μm single-mode cable

ICS-2102T: 50/125μm or 62.5/125μm multi-mode fiber cable

ICS-2102TS: 9/125μm single-mode cable
ESD Protection6KV
Surge Protection2KV
Hardware
InstallationDIN-rail kit and wall-mount ear
EnclosureIP 30 metal
Dimensions (W x D x H)32 x 87.8 x 135 mm
WeightICS-2105AT: 390g
ICS-2102T: 386g
ICS-2102TS: 391g
LED IndicatorsSystem: Power 1, Power 2, Fault, SYS
SFP: Link/Active
Serial Port: Tx and Rx
Power Requirements9~48V DC / 24V AC, redundant power with reverse polarity protection
Power ConsumptionICS-2105AT:
Full Loading
9VDC: 0.44A (3.96 watts)
12VDC: 0.33A (4 watts)
24VDC: 0.17A (4.08 watts)
48VDC: 0.1A (4.8 watts)

ICS-2102T:
Full Loading
9VDC: 0.56A (5 watts)
12VDC: 0.42A (5 watts)
24VDC: 0.23A (5.5 watts)
48VDC: 0.13A (6 watts)

ICS-2102TS:
Full Loading
9VDC: 0.56A (5 watts)
12VDC: 0.42A (5 watts)
24VDC: 0.23A (5.5 watts)
48VDC: 0.13A (6 watts)
ConnectorRemovable 6-pin terminal block for power input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2
AlarmProvides one relay output for power failure
Alarm relay current carry ability: 1A @ DC 24V
Reset Button< 5 sec: System reboot
> 5 sec: Factory default
Management
Management InterfacesWeb management
Telnet Console management
Windows-based VCOM Utility management
SNMPv1, v2c / SNMP Trap
UNI-NMS monitoring
PLANET Smart Discovery Utility
IP VersionIPv4 and IPv6
Operation ModeTCP Server
TCP Client
UDP Client
Virtual COM
RFC2217
Telnet Server
Pair Connection – Remote (Slave)
Pair Connection – Local (Master)
Modbus converter server / client
Virtual COM Utility Platform SupportsWindows-based only:
Windows XP
Windows Server 2003
Windows 7
Windows Server 2008
Windows 8 (Must install the latest version of WinPcap)
Windows Server 2012 (Must install the latest version of WinPcap)
Windows 10
SecurityAllows maximum 4 accessible IP address hosts/ranges
SNMP MIBsRFC1213 MIB-II
RFC1317 RS232-like MIB
Standards Conformances
Regulatory ComplianceFCC Part 15 Class A,
CE Certification Class A
RoHS
Stability TestingIEC60068-2-32 (Free fall)
IEC60068-2-27 (Shock)
IEC60068-2-6 (Vibration)
StandardsIEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-FX
RFC 768 UDP
RFC 793 TFTP
RFC 791 IP
RFC 792 ICMP
RFC 854 Telnet
RFC 958 NTP
RFC 1591 DNS (client only)
RFC 1908 SNMPv2c
RFC 2068 HTTP
RFC 2131 DHCP Client
RFC 2732 Format for Literal IPv6 Addresses in URL's
RFC 3315 DHCPv6 Client
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNSv6
RFC 4443 ICMPv6
EIA/TIA RS232/422/485
Environment
Operating Temperature-40 ~ 75 degrees C
Storage Temperature-40 ~ 85 degrees C
Humidity5 ~ 95% (non-condensing)

 

Datasheet

DateVersionDescriptionDownload
2020-10-161.0ICS-2105AT / ICS-2102T / ICS-2102TS

 

Firmware

DateVersionDescriptionDownload
2021-10-221.155b210805Bug Fixed -
1. Make up the missing Modbus Converter Server / Client Mode
2. Fixed the problem that the "green" LED will unconditionally turn on when using RS422 and RS485
3. Fixed the problem that Smart Discovery cannot scan

 

Quick Guide

DateVersionDescriptionDownload
2022-12-141.2Add ICS-2102T / ICS-2102TS.
2020-04-071.1Release for ICS-2105AT

 

User's Manual

DateVersionDescriptionDownload
2023-04-211.2Modify contents of user manual.
2020-07-301.1Initial release.

 

Utility

DateVersionDescriptionDownload
2020-12-112011041000_2521_1337_11111. Supports starting as service mode.
2. Supports simplified Chinese
*Note:This utility is only for the ICS-110, ICS-120, ICS-115A, ICS-2100T, ICS-2102T, ICS-2102TS, ICS-2105AT, ICS-2200T, and ICS-2400T and NOT compatible with ICS-100, ICS-105A, ICS-2100, and ICS-2105A.

 

EC Declaration

DateVersionDescriptionDownload
2023-12-261.0EC Declaration.