- Διαθεσιμοτητα: Άμεσα Διαθέσιμο
- Κατασκευαστης: PLANET
- Κωδικος Προϊοντος: IGS-4215-8UP2T2S
- Βαρος: 1.57kg
- Διαστασεις: 10.73 x 7.68 x 15.20
Cost-optimized Full PoE++ Power Solution Ideal for Hardened Environment
Designed to be installed in heavy industrial environments, the IGS-4215-8UP2T2S is the new member of PLANET Industrial-grade, DIN-rail type L2/L4 Managed Gigabit PoE++ Switch family featuring PLANET intelligent PoE functions to improve the availability of critical business applications. It provides IPv6/IPv4 dual stack management and built-in L2/L4 Gigabit switching engine along with 8 10/100/1000BASE-T ports featuring 95-watt 802.3bt PoE++, 2 additional Gigabit copper ports and another 2 extra 100/1000BASE-X SFP fiber slots for data and video uplink. The IGS-4215-8UP2T2S is able to operate reliably, stably and quietly in any hardened environment without affecting its performance. It comes with a total power budget of up to 360 watts for different kinds of PoE applications and operating temperature ranging from -40 to 75 degrees C in a rugged IP30 metal housing.
802.3bt PoE++ 90~95-watt Power over 4-pair UTP Solution
As the IGS-4215-8UP2T2S adopts the IEEE 802.bt PoE++ standard, it is capable to source up to 95 watts of power by using all the four pairs of standard Cat5e/6 Ethernet cabling to deliver power and full-speed data to each remote PoE compliant powered device (PD). It possesses triple amount of power capability than the conventional 802.3at PoE+ and is an ideal solution to satisfy the growing demand for higher power consuming network PDs, such as:
- PoE PTZ speed dome cameras
- Network devices
- Thin clients
- AIO (all-in-one) touch PCs, point of sale (POS) and information kiosks
- Remote digital signage displays
- PoE lightings
802.3bt PoE++ and Advanced PoE Power Output Mode Management
To meet the demand of various powered devices consuming stable PoE power, the IGS-4215-8UP2T2S provides four different PoE power output modes for selection.
- 95W 802.3bt PoE++ Power Output Mode
- 95W Force Power Output Mode
- 36W End-span PoE Power Output Mode
- 36W Mid-span PoE Power Output Mode
Built-in Unique PoE Functions for Powered Devices Management
As the industrial PoE++ managed switch for surveillance, wireless and VoIP networks, the IGS-4215-8UP2T2S features special PoE management functions:
- PD alive check
- Scheduled power recycling
- PoE schedule
- PoE usage monitoring
- PoE extension
Intelligent Powered Device Alive Check
The IGS-4215-8UP2T2S can be configured to monitor connected PD (powered device) status in real time via ping action. Once the PD stops working and responding, the IGS-4215-8UP2T2S will resume the PoE port power and bring the PD back to work. It will greatly enhance the network reliability through the PoE port resetting the PD’s power source and reducing the administrator’s management burden.
Scheduled Power Recycling
The IGS-4215-8UP2T2S allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specified time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow.
PoE Schedule for Energy Savings
Under the global trend of energy saving and contributing to environmental protection, the IGS-4215-8UP2T2S can effectively control the power supply besides its capability of giving high watts power. The “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals, which is a powerful function to help SMBs or enterprises save power and budget. It also increases security by powering off PDs that should not be in use during non-business hours.
802.3bt PoE++ Power and Ethernet Data Transmission Distance Extension
In the “Extend” operation mode, the IGS-4215-8UP2T2S operates on a per-port basis at 10Mbps duplex operation but can support 83-watt PoE power output over a distance of up to 250 meters overcoming the 100m limit on Ethernet UTP cable. With this brand-new feature, the IGS-4215-8UP2T2S provides an additional solution for 802.3at/af PoE distance extension, thus saving the cost of Ethernet cable installation.
Intelligent LED Indicators for Real-time PoE Usage Monitoring
Via the power usage chart in the web management interface, the IGS-4215-8UP2T2S enables the administrator to monitor the status of the power usage of the connected PDs in real time. Thus, it greatly enhances the management efficiency of the facilities. Moreover, the IGS-4215-8UP2T2S helps users to monitor the current status of PoE power usage easily and efficiently via its advanced LED indication. Called “PoE Power Usage”, the front panel of the IGS-4215-8UP2T2S has four amber LEDs indicating four different PoE power usages, namely 90W, 180W, 270W and 360W.
Cybersecurity Network Solution to Minimize Security Risks
The IGS-4215-8UP2T2S comes with enhanced cybersecurity to fend off cyberthreats and cyberattacks. It supports SSHv2 and TLSv1.2 protocols to provide strong protection against advanced threats. Served as a key point to transmit data over a long-distance fiber optic cable to customer's critical equipment in a business network, the cybersecurity feature of the IGS-4215-8UP2T2S protects the switch management and enhances the security of the mission-critical network without any extra deployment cost and effort.
Redundant Ring, Fast Recovery for Critical Network Applications
The IGS-4215-8UP2T2S supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology, Spanning Tree Protocol (802.1s MSTP) into customer’s network to enhance system reliability and uptime in various environments.
Environmentally Hardened Design
With the IP30 aluminum industrial case, the IGS-4215-8UP2T2S provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curb-side traffic control cabinets without air conditioner. Being able to operate under the temperature range from -40 to 75 degrees C, the IGS-4215-8UP2T2S can be placed in almost any difficult environment.
Robust Protection
The IGS-4215-8UP2T2S provides contact discharge of ±6KV DC and air discharge of ±8KV DC for Ethernet ESD protection. It also supports ±4KV surge immunity to improve product stability and protects users’ networks from devastating ESD attacks, making sure the flow of operation does not fluctuate.
IPv6/IPv4 Dual Stack Management
Supporting both IPv6 and IPv4 protocols, the IGS-4215-8UP2T2S helps the SMBs to step in the IPv6 era with the lowest investment as its network facilities need not be replaced or overhauled if the IPv6 FTTx edge network is set up.
Robust Layer 2 Features
The IGS-4215-8UP2T2S can be programmed for advanced switch management functions such as dynamic port link aggregation, 802.1Q VLAN, Q-in-Q VLAN, Multiple Spanning Tree Protocol (MSTP), loop and BPDU guard, IGMP snooping, and MLD snooping. Via the link aggregation, the IGS-4215-8UP2T2S allows the operation of a high-speed trunk to combine with multiple ports such as an 8Gbps fat pipe, and supports fail-over as well. Also, the Link Layer Discovery Protocol (LLDP) is the Layer 2 protocol included to help discover basic information about neighboring devices on the local broadcast domain.
Efficient Traffic Control
The IGS-4215-8UP2T2S is loaded with robust QoS features and powerful traffic management to enhance services to business-class data, voice, and video solutions. The functionality includes broadcast/multicast/unicast storm control, per port bandwidth control, 802.1p/CoS/IP DSCP QoS priority and remarking. It guarantees the best performance in VoIP and video stream transmission, and empowers the enterprises to take full advantage of the limited network resources.
Powerful Security
PLANET IGS-4215-8UP2T2S offers comprehensive IPv4/IPv6 Layer 2 to Layer 4 Access Control List (ACL) for enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP/UDP ports or defined typical network applications. Its protection mechanism also comprises 802.1X port-based user and device authentication, which can be deployed with RADIUS to ensure the port level security and block illegal users. With the protected port function, communication between edge ports can be prevented to guarantee user privacy. Furthermore, Port security function allows to limit the number of network devices on a given port. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.
Advanced Network Security
The IGS-4215-8UP2T2S also provides DHCP Snooping, IP Source Guard and Dynamic ARP Inspection functions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.
User-friendly and Secure Management
For efficient management, the IGS-4215-8UP2T2S is equipped with Command line, Web and SNMP management interfaces.
- With the built-in Web-based management interface, the IGS-4215-8UP2T2S offers an easy-to-use, platform-independent management and configuration facility.
- For text-based management, it can be accessed via Telnet and the console port.
- By supporting the standard SNMP protocol, the switch can be managed via any SNMP-based management software.
Moreover, the IGS-4215-8UP2T2S offers secure remote management by supporting SSHv2, TLSv1.2 and SNMP v3 connections which encrypt the packet content at each session.
Remote Management Solution
PLANET's Universal Network Management System (UNI-NMS) and CloudViewer app support IT staff by remotely managing all network devices and monitoring PDs' operational statuses. Thus, they're designed for both the enterprises and industries where deployments of PDs can be as remote as possible, without having to go to the actual location once a bug or faulty condition is found. With the UNI-NMS or CloudViewer app, all kinds of businesses can now be speedily and efficiently managed from one platform.
Flexible Long-distance Extension Solution
The IGS-4215-8UP2T2S provides 2 extra Gigabit TP interfaces supporting 10/100/1000BASE-T RJ45 copper to connect with surveillance network devices such as NVR, Video Streaming Server or NAS to facilitate surveillance management. Or through the two dual-speed fiber SFP slots, it can also connect with the 100BASE-FX /1000BASE-SX/LX SFP (Small Form-factor Pluggable) fiber transceiver to uplink to backbone switch and monitoring center in long distance. The distance can be extended from 550 meters to 2 kilometers (multi-mode fiber) and to 10/20/40/60/80/120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions.
Intelligent SFP Diagnosis Mechanism
The IGS-4215-8UP2T2S supports SFP-DDM (Digital Diagnostic Monitor) function that can easily monitor real-time parameters of the SFP for the network administrator, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.
Industrial-grade PoE++ Switch for Building Automation and Security
Suitable for buildings where security is strictly to be enforced, the IGS-4215-8UP2T2S, with up to eight 802.3bt PoE++, in-line power interfaces, can easily build a power centrally controlled for an IP phone system, IP surveillance system, and wireless AP group in the harsh Industrial environment. For instance, 8 PoE IP cameras or PoE wireless APs can be easily installed for surveillance demands or a wireless roaming environment in the industrial area can be built. Without the power-socket limitation, the IGS-4215-8UP2T2S makes the installation of IP cameras or wireless APs easier and more efficient.
Perfect Integration Solution for IP PoE Camera and NVR System
The IGS-4215-8UP2T2S provides 8 10/100/1000BASE-T 802.3bt PoE++ ports which can offer sufficient PoE power to multiple PoE IP cameras at the same time. In addition, with the two 100/1000BASE-X SFP interfaces, the IGS-4215-8UP2T2S can connect to a core fiber switch and send video streams to an NVR and monitoring center. Through the high-performance switch architecture, the IGS-4215-8UP2T2S facilitates the recorded video files from the 8 PoE++ IP cameras to be saved in the NVR systems. Furthermore, the NVR systems can be controlled and monitored in both the local LAN and the remote site via Internet. The IGS-4215-8UP2T2S undoubtedly brings an ideal secure surveillance system at a lower total cost.
ITU-T G.8032 ERPS Makes Data Transmission Uninterrupted
The IGS-4215-8UP2T2S features strong rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology into customer’s automation network to enhance system reliability and uptime. Applying the IEEE 802.3bt Power over Ethernet standard, the IGS-4215-8UP2T2S can directly connect with any IEEE 802.3bt end-nodes like PTZ (Pan, Tilt & Zoom) network cameras and speed dome cameras. The IGS-4215-8UP2T2S can easily help system integrators with the available network infrastructure to build wireless AP, IP camera and VoIP systems where power can be centrally-controlled.
Physical Port
- 8 10/100/1000BASE-T Gigabit Ethernet RJ45 ports with IEEE 802.3bt PoE++ Injector function
- 2 10/100/1000BASE-T Gigabit Ethernet RJ45 ports
- Two 100/1000BASE-X SFP slots for SFP type auto detection
- One RJ45 console interface for basic management and setup
Power over Ethernet
- Complies with IEEE 802.3bt Power over Ethernet Plus Type-4 PSE
- Backward compatible with IEEE 802.3af/at PD device
- Up to 8 ports of IEEE 802.3af/802.3at/802.3bt PoE++ devices powered
- 360-watt PoE budget
- Supports PoE power up to 95 watts for each PoE port
- Auto detects powered device (PD)
- Circuit protection prevents power interference between ports
- Remote power feeding up to 100 meters in standard mode and 250m in extend mode
- PoE management
- Total PoE power budget control
- Per port PoE function enable/disable
- PoE port power feeding priority
- Per PoE port power limitation
- PD classification detection
- Intelligent PoE features
- PD alive check
- PoE schedule
Industrial Hardened Design
- 48~54V DC, redundant power with reverse polarity protection
- DIN-rail and wall-mount designs
- IP30 aluminum case
- Supports 6KV DC Ethernet ESD protection
- -40 to 75 degrees C operating temperature
Layer 2 Features
- Supports VLAN
- IEEE 802.1Q tagged VLAN
- Provider bridging (VLAN Q-in-Q, IEEE 802.1ad) support
- Protocol VLAN
- Voice VLAN
- Private VLAN (Protected port)
- Management VLAN
- GVRP
- Supports Spanning Tree Protocol
- IEEE 802.1D Spanning Tree Protocol (STP)
- IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
- IEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN
- STP BPDU Guard, BPDU Filtering and BPDU Forwarding
- Supports Link Aggregation
- IEEE 802.3ad Link Aggregation Control Protocol (LACP)
- Cisco ether-channel (static trunk)
- Maximum 6 trunk groups, up to 8 ports per trunk group
- Provides port mirror (many-to-1)
- Loop protection to avoid broadcast loops
- Supports ERPS (Ethernet Ring Protection Switching)
- Link Layer Discovery Protocol (LLDP)
Quality of Service
- Ingress/Egress Rate Limit per port bandwidth control
- Traffic classification
- IEEE 802.1p CoS
- IP TCP/UDP port number
- Typical network application
- Strict priority and Weighted Round Robin (WRR) CoS policies
- Supports QoS and In/Out bandwidth control on each port
- Traffic-policing on the switch port
- DSCP remarking
Multicast
- Supports IPv4 IGMP snooping v2, v3
- Supports IPv6 MLD snooping v1, v2
- IGMP querier mode support
- IGMP snooping port filtering
- MLD snooping port filtering
Security
- Storm Control support
- Broadcast/ unknown multicast/unknown unicast
- Authentication
- IEEE 802.1X port-based network access authentication
- Built-in RADIUS client to cooperate with the RADIUS servers
- DHCP Relay and DHCP Option 82
- RADIUS/TACACS+ users access authentication
- Access Control List
- IPv4/IPv6 IP-based ACL
- IPv4/IPv6 IP-based ACE
- MAC-based ACL
- MAC-based ACE
- MAC Security
- Static MAC
- MAC filtering
- Port security for source MAC address entries filtering
- DHCP snooping to filter distrusted DHCP messages
- Dynamic ARP inspection discards ARP packets with invalid MAC address to IP address binding
- IP source guard prevents IP spoofing attacks
- DoS attack prevention
Management
- IPv4 and IPv6 dual stack management
- Switch Management Interface
- Web switch management
- Console/Telnet Command Line Interface
- SNMP v1 and v2c switch management
- SSHv2, TLSv1.2 and SNMP v3 secure access
- SNMP Management
- SNMP trap for interface Link Up and Link Down notification
- Four RMON groups (history, statistics, alarms and events)
- User privilege levels control
- Built-in Trivial File Transfer Protocol (TFTP) client
- Static and DHCP for IP address assignment
- System Maintenance
- Firmware upload/download via HTTP/TFTP
- Configuration upload/download through HTTP/TFTP
- Dual images
- Hardware reset button for system reboot or reset to factory default
- SNTP Network Time Protocol
- Network Diagnostic
- Cable diagnostics
- ICMPv6/ICMPv4 Remote Ping
- SFP-DDM (Digital Diagnostic Monitor)
- Link Layer Discovery Protocol (LLDP) Protocol and LLDP-MED
- Event message logging to remote syslog server
- PLANET Smart Discovery Utility for deployment management
- PLANET NMS system and CloudViewer for deployment management
Hardware Specifications | |
---|---|
Copper Ports | Ten 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports (Ports 1 to 10) |
PoE Injector Port | Eight ports with 802.3af/802.3at/802.3bt PoE++ injector function (Ports 1 to 8) |
SFP Ports | Two 1000BASE-SX/LX/BX SFP interfaces (Ports 11 to 12) Compatible with 100BASE-FX SFP |
Console | 1 x RS232-to-RJ45 serial port (115200,8, N, 1) |
RAM | 128Mbytes |
Flash Memory | 16Mbytes |
Reset Button | < 5 sec: System reboot > 5 sec: Factory default |
Connector | Removable 6-pin terminal block Pin 1/2 for Power 1 ; Pin 3/4 for fault alarm ; Pin 5/6 for Power 2 |
Alarm | One relay output for power failure. Alarm relay current carry ability: 1A @ 24V AC |
Power Requirements | 48~54V DC,8.5A (max.) (>52V DC for PoE++ output recommended) |
Power Consumption/ Dissipation | System On:Max. 9.18 watts/31.3BTU PoE Full Loading: Max. 390 watts/1329.9BTU |
Dimensions (W x D x H) | 76.8 x 107.3 x 152 mm |
Weight | 1,091g |
Enclosure | IP30 aluminum case |
Installation | DIN-rail kit and wall-mount ear |
ESD Protection | Contact Discharge 6KV DC Air Discharge 8KV DC |
Surge Protection | 4KV DC |
LED | System: Power 1 (Green) Power 2 (Green) Fault Alarm (Red) Ring (Green) R.O.( Green) Per 10/100/1000T RJ45 PoE++ Ports: 1000Mbps LNK/ACT (Green) 10/100Mbps LNK/ACT (Amber) 802.3bt PoE++-in-use x 1 (Green) 802.3at/af PoE-in-use x 1 (Amber) Per 10/100/1000T RJ45Ports:, 1000 LNK/ACT (Green) 10/100 LNK/ACT (Amber) Per SFP Interface: 1000 LNK/ACT (Green) 100 LNK/ACT (Amber) PoE Usage: 90W, 180W, 270W, 360W (Amber) |
Switching Specifications | |
Switch Architecture | Store-and-Forward |
Switch Fabric | 24Gbps/non-blocking |
Switch Throughput@64 bytes | 17.85Mpps |
MAC Address Table | 8K entries |
Shared Data Buffer | 4.1 megabits |
Flow Control | IEEE 802.3x pause frame for full duplex Back pressure for half duplex |
Jumbo Frame | 10 Kbytes |
Power over Ethernet | |
PoE Standard | IEEE 802.3bt PoE++ Type-4 |
PoE Power Supply Type | End-span Mid-span BT |
Power Pin Assignment | 802.3bt/UPoE: 1/2(-), 3/6(+),4/5(+), 7/8(-) 802.3at/PoE: End-span: 1/2(-), 3/6(+) 802.3at/PoE: Mid-span: 4/5(+), 7/8(-) |
PoE Power Output | Per port 48V ~ 54V DC 802.3bt Type-4 mode: maximum 95 watts End-span mode: maximum 36 watts Mid-span mode: maximum 36 watts Force mode: maximum 95 watts |
PoE Power Budget | Single power input: 240W maximum (depending on power input) Dual power input: 360W maximum (depending on power input) ※Dual power input must be the same as DC voltage, like dual 54V. |
Number of 90W 802.3bt Type-4 PDs | 4 |
Number of 60W 802.3bt Type-3 PDs | 6 |
Number of 30W 802.3at Type-2 PDs | 8 |
PoE Management Functions | |
Enhanced PoE Mode | Standard/Legacy/Force |
PoE Management | PD Alive Check Scheduled Power Recycling PoE Schedule PoE Usage Monitoring PoE Extension |
Active PoE Device Live Detection | Yes |
PoE Power Recycling | Yes, daily or predefined schedule |
PoE Schedule | 4 schedule profiles |
PoE Extend Mode | Yes, max. up to 250 meters |
Layer 2 Functions | |
Port Mirroring | TX/RX/Both Many-to-1 monitor Up to 4 sessions |
VLAN | 802.1Q tagged VLAN 802.1ad Q-in-Q tunneling (VLAN stacking) Voice VLAN Protocol VLAN Private VLAN (Protected port) GVRP Management VLAN Up to 256 VLAN groups, out of 4094 VLAN IDs |
Link Aggregation | IEEE 802.3ad LACP and static trunk Supports 6 groups with 8 ports per trunk |
Spanning Tree Protocol | IEEE 802.1D Spanning Tree Protocol (STP) IEEE 802.1w Rapid Spanning Tree Protocol (RSTP) IEEE 802.1s Multiple Spanning Tree Protocol (MSTP) STP BPDU Guard, BPDU Filtering and BPDU Forwarding |
IGMP Snooping | IPv4 IGMP snooping v2, v3 IGMP querier Up to 256 multicast groups |
MLD Snooping | IPv6 MLD snooping v2, v3, up to 256 multicast groups |
Access Control List | IPv4/IPv6 IP-based ACL/MAC-based ACL IPv4/IPv6 IP-based ACE/MAC-based ACE |
QoS | 8 mapping IDs to 8 level priority queues Port number 802.1p priority DSCP/IP precedence of IPv4/IPv6 packets Traffic classification based, strict priority and WRR Ingress/Egress Rate Limit per port bandwidth control |
Ring | Supports ERPS, and complies with ITU-T G.8032 Recovery time < 450ms |
Security Functions | |
Access Control List | IPv4/IPv6 IP-based ACL/MAC-based ACL IPv4/IPv6 IP-based ACE/MAC-based ACE Max. 256 ACL entries |
Port Security | IEEE 802.1X – Port-based authentication Built-in RADIUS client to co-operate with RADIUS server RADIUS/TACACS+ user access authentication |
MAC Security | IP-MAC port binding MAC filter Static MAC address, max. 256 static MAC entries |
Enhanced Security | DHCP Snooping and DHCP Option82 STP BPDU guard, BPDU filtering and BPDU forwarding DoS attack prevention ARP inspection IP source guard |
Management Functions | |
Basic Management Interfaces | RS232 to RJ45 Console Web browser Telnet SNMP v1, v2c |
Secure Management Interfaces | SSHv2, TLS v1.2, SNMP v3 |
System Management | Firmware upgrade by HTTP/TFTP protocol through Ethernet network Configuration upload/download through HTTP/TFTP LLDP protocol SNTP PLANET Smart Discovery Utility PLANET NMS System/CloudViewer |
Event Management | Remote/Local Syslog System log |
SNMP MIBs | RFC 1213 MIB-II RFC 1215 Generic Traps RFC 1493 Bridge MIB RFC 2674 Bridge MIB Extensions RFC 2737 Entity MIB (Version 2) RFC 2819 RMON (1, 2, 3, 9) RFC 2863 Interface Group MIB RFC 3635 Ethernet-like MIB RFC 3621 Power Ethernet MIB |
Standards Conformance | |
Regulatory Compliance | FCC Part 15 Class A EN 55032 EN 55035 ICES-003 issue 7 |
Stability Testing | IEC 60068-2-32 (free fall) IEC 60068-2-27 (shock) IEC 60068-2-6 (vibration) |
Standards Compliance | IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX/100BASE-FX IEEE 802.3z Gigabit SX/LX IEEE 802.3ab Gigabit 1000BASE-T IEEE 802.3x Flow Control and Back Pressure IEEE 802.3ad Port Trunk with LACP IEEE 802.1D Spanning Tree Protocol IEEE 802.1w Rapid Spanning Tree Protocol IEEE 802.1s Multiple Spanning Tree Protocol IEEE 802.1p Class of Service IEEE 802.1Q VLAN Tagging IEEE 802.1x Port Authentication Network Control IEEE 802.1ab LLDP IEEE 802.3af Power over Ethernet IEEE 802.3at Power over Ethernet Plus IEEE 802.3az for Energy-Efficient Ethernet RFC 768 UDP RFC 783 TFTP RFC 791 IP RFC 792 ICMP RFC 2068 HTTP RFC 1112 IGMP v1 RFC 2236 IGMP v2 RFC 3376 IGMP v3 RFC 2710 MLD v1 RFC 3810 MLD v2 ITU G.8032 ERPS Ring |
Environment | |
Operating Temperature | -40 ~ 75 degrees C |
Storage Temperature | -40 ~ 85 degrees C |
Humidity | 5 ~ 95% (non-condensing) |
Datasheet
Date | Version | Description | Download |
---|---|---|---|
2023-03-10 | 1.0 | IGS-4215-8UP2T2S |
Firmware
Date | Version | Description | Download |
---|---|---|---|
2023-05-12 | 1.305b230426 | Fixed PoE Management Mode that might be set incorrectly when powering on. |
Quick Guide
Date | Version | Description | Download |
---|---|---|---|
2024-07-05 | 2.2 | Added PSTI function. | |
2023-09-23 | 1.1 | Add IGS-4215-16P2T2S. | |
2023-01-07 | 1.0 | Initial release. |
User's Manual
Date | Version | Description | Download |
---|---|---|---|
2023-02-04 | 1.3 | Initial release. |
EC Declaration
Date | Version | Description | Download |
---|---|---|---|
2023-04-27 | 1.0 | EC Declaration. |