Menu
Καλάθι Αγορών

PLANET IGT-900-2T2S Industrial 2-Port 10/100/1000T + 2-Port 100/1000/2500X SFP Managed Media Converter

PLANET IGT-900-2T2S Industrial 2-Port 10/100/1000T + 2-Port 100/1000/2500X SFP Managed Media Converter
PLANET IGT-900-2T2S Industrial 2-Port 10/100/1000T + 2-Port 100/1000/2500X SFP Managed Media Converter
PLANET IGT-900-2T2S Industrial 2-Port 10/100/1000T + 2-Port 100/1000/2500X SFP Managed Media Converter
PLANET IGT-900-2T2S Industrial 2-Port 10/100/1000T + 2-Port 100/1000/2500X SFP Managed Media Converter
PLANET IGT-900-2T2S Industrial 2-Port 10/100/1000T + 2-Port 100/1000/2500X SFP Managed Media Converter
PLANET IGT-900-2T2S Industrial 2-Port 10/100/1000T + 2-Port 100/1000/2500X SFP Managed Media Converter
PLANET IGT-900-2T2S Industrial 2-Port 10/100/1000T + 2-Port 100/1000/2500X SFP Managed Media Converter
  • Διαθεσιμοτητα: Άμεσα Διαθέσιμο
  • Κατασκευαστης: PLANET
  • Κωδικος Προϊοντος: IGT-900-2T2S
  • Βαρος: 0.59kg
  • Διαστασεις: 8.70 x 3.20 x 13.50
271,72€
Χωρίς ΦΠΑ: 219,13€

Supreme Managed Media Converter for Robust Environment 

PLANET IGT-900-2T2S, a fully-managed Gigabit Media Converter for harsh environments, features two 10/100/1000Mbps copper ports, two 100/1000/2500X SFP ports and redundant power system in an IP30 rugged but compact-sized case. The IGT-900-2T2S can be installed in any difficult environment as it can operate stably under the temperature range from -40 to 75 degrees C. With such a slim enclosure, it does not need a big space to install. The switch features user-friendly yet advanced IPv6/IPv4 management interfaces, abundant L2/L4 switching functions and Layer 3 static routing capability. It allows either DIN-rail or wall mounting for efficient use of cabinet space. With SFP fiber slots, it can be flexibly applied to extend the connection distance. 

 

 

Enhanced Smart Management Features

The IGT-900-Series provides auto MDI/MDI-X on its TP port and built-in Link Fault Pass-through function (LFP). The LFP function includes Link Loss Carry Forward (LLCF) and Link Loss Return (LLR), both of which can immediately alarm administrators the problem of the link media and provide efficient solution to monitoring the net. 

  •  LLCF means when a device connected to the converter and the TP line loses the link, the converter’s fiber port will disconnect the link of transmission. 
  •  LLR means when a device connected to the converter and the fiber line loses the link, the converter’s fiber port will disconnect the link of transmission. 

Therefore, the IGT-900-2T2S greatly supports the administrators to manage the network efficiently.  

 

 

Port Backup mode

Via the managed interface, the IGT-900-2T2S can be configured port backup mode. when in the port backup mode, it provides rapid copper/fiber redundancy of link for highly critical Ethernet applications. The port backup mode also supports auto-recovering function. If the destination port of a packet is link down, it will forward the packet to the other port of the backup pair.

 

 

Network with Cybersecurity Helps Minimize Security Risks

The IGT-900-Series comes with enhanced cybersecurity to fend off cyberthreats and cyberattacks. It supports SSHv2, TLSv1.2 and SNMPv3 protocols to provide strong protection against advanced threats. Served as a key point to transmit data to customer's critical equipment in a business network, the cybersecurity feature of the IGT-900-Series protects the management and enhances the security of the mission-critical network without any extra deployment cost and effort.

 

 

 

Redundant Ring, Fast Recovery for Critical Network Applications

The IGT-900-Series supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology, Spanning Tree Protocol (802.1s MSTP), and redundant power input system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a certain simple Ring network, the recovery time of data link can be as fast as 10ms.

 

SMTP/SNMP Trap Event Alert

The IGT-900-Series provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.

 

Effective Alarm Alert for Better Protection

The IGT-900-Series supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource.

 

Robust Layer 2 Features

The IGT-900-Series can be programmed for advanced Layer 2 switch management functions such as dynamic port link aggregation, 802.1Q tagged VLAN, Q-in-Q VLAN, private VLAN, Multiple Spanning Tree Protocol (MSTP), Layer 2 to Layer 4 QoS, bandwidth control, IGMP snooping and MLD snooping. Via the aggregation of supporting ports, the IGT-900-Series allows the operation of a high-speed trunk group that comes with multiple ports and supports fail-over as well.

 

Efficient Management

For efficient management, the IGT-900-Series is equipped with CLI, Web GUI and SNMP management interfaces. 

  •  With the built-in Web-based management interface, it offers an easy-to-use, platform-independent management and configuration facility. 
  •  For text-based management, it can be accessed via Telnet/SSH.
  •  For standard-based monitor and management software, it offers SNMPv3 connection which encrypts the packet content at each session for secure remote management.

 

Powerful Network Security

The IGT-900-Series offers comprehensive Layer 2 to Layer 4 Access Control List (ACL) for enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP/UDP ports or defined typical network applications. Its protection mechanism also comprises 802.1X Port-based and MAC-based user and device authentication. With the private VLAN function, communication between edge ports can be prevented to ensure user privacy. 

 

Advanced IP Network Protection

The IGT-900-Series also provides DHCP Snooping, IP Source Guard and Dynamic ARP Inspection functions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.

 

Intelligent SFP Diagnosis Mechanism

The IGT-900-Series supports SFP-DDM (digital diagnostic monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP transceivers, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.

 

 

 

1588 Time Protocol for Industrial Computing Networks

The IGT-900-Series is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.

 

 

Modbus TCP Provides Flexible Network Connectivity for Factory Automation

With the supported Modbus TCP/IP Protocol, the IGT-900-Series can easily integrate with SCADA systems, HMI systems and other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s operating information, port information and communication status, thus easily achieving enhanced monitoring and maintenance of the entire factory.

Hardened Environment Application

PLANET IGT-900-Series offers full port Gigabit speed. It provides very high reliability and security features to make sure the continuous operation in harsh environments such as transportations, factories, outdoors and places where extremely low or high temperatures can be experienced. Moreover, the IGT-900-Series is also compatible with 100Mbps, 1000Mbps and 2500Mbps SFP transceivers to provide a strong, stable and long-distance connection and flexible industrial networking deployment. 

 

 

 

 

Fiber-Optic Link Capability Enables Extension of Network Deployment

The SFP slots built in the IGT-900-Series support dual speed as it features 100BASE-FX and 1000/2500BASE-SX/LX SFP (Small Form-factor Pluggable) fiber-optic modules. Now the administrator can flexibly choose the suitable SFP transceiver according to not only the transmission distance, but also the transmission speed required. The distance can be extended from 550 meters to 2km (multi-mode fiber) and up to 10/20/40/60/80/120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions.

 

Physical Port

  • 2 10/100/1000BASE-T Gigabit Ethernet RJ45 ports
  • 2 100/1000/2500BASE-X SFP ports for SFP type auto detection

 

Industrial Protocol

  • Modbus TCP for real-time monitoring in the SCADA system
  • IEEE 1588v2 PTP (Precision Time Protocol) transparent clock mode

 

Industrial Case and Installation

  • IP30 metal  case 
  • DIN-rail or wall-mount design
  • 24V AC, 9~48V DC, redundant power with reverse polarity protection
  • Supports 6KV DC Ethernet ESD protection
  • -40 to 75 degrees C operating temperature 

 

Layer 3 IP Routing Features

  • Supports maximum 32 static routes and route summarization
  • Routing interface provides per VLAN routing mode

 

Layer 2 Features

  • Storm Control support
    • Broadcast/Multicast/Unicast
  • Supports VLAN
    • IEEE 802.1Q tagged VLAN
    • Supports provider bridging (VLAN Q-in-Q, IEEE 802.1ad) 
    • Private VLAN Edge (PVE)
    • Port Isolation
    • MAC-based VLAN
    • IP Subnet-based VLAN
    • Protocol-based VLAN
    • VLAN Translation
    • Voice VLAN
    • GVRP
  • Supports Spanning Tree Protocol
    • IEEE 802.1D Spanning Tree Protocol (STP)
    • IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
    • IEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN
    • BPDU Filtering/BPDU Guard
  • Supports Link Aggregation
    • 802.3ad Link Aggregation Control Protocol (LACP)
    • Cisco ether-channel (static trunk)
    • Maximum 2 trunk groups with 2 ports per trunk group 
    • Up to 5Gbps bandwidth (duplex mode) 
  • Provides port mirror (many-to-1)
  • Port mirroring to monitor the incoming or outgoing traffic on a particular port 
  • Loop protection to avoid broadcast loops
  • Supports ERPS (Ethernet Ring Protection Switching)
  • Compatible with Cisco Uni-directional link detection (UDLD) that monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices
  • Link Layer Discovery Protocol (LLDP) 
  • IEEE 802.3ah OAM

 

Link Fault Passthrough (LFP)

  • The IGT-900-1T1S supports one group (TP Port 1 and SFP Port 2) LFP function.
  • The IGT-900-2T2S supports two groups (TP Port 1 and SFP Port 3, TP Port 2 and SFP Port 4) LFP function.

 

Port Backup 

  • The IGT-900-2T2S supports two backup groups. 

 

Quality of Service

  • Ingress Shaper and Egress Rate Limit per port bandwidth control
  • 8 priority queues on all switch ports
  • Traffic classification
    • IEEE 802.1p CoS
    • IP TOS/DSCP/IP precedence
    • IP TCP/UDP port number
    • Typical network application
  • Strict priority and Weighted Round Robin (WRR) CoS policies
  • Supports QoS and In/Out bandwidth control on each port
  • Traffic-policing on the switch port
  • DSCP remarking

 

Multicast

  • Supports IPv4 IGMP snooping v1, v2 and v3
  • Supports IPv6 MLD snooping v1 and v2
  • Querier mode support
  • IPv4 IGMP snooping port filtering
  • IPv6 MLD snooping port filtering
  • MVR (Multicast VLAN Registration)

 

Security

  • Authentication
    • IEEE 802.1x port-based/MAC-based network access authentication
    • Built-in RADIUS client to co-operate with the RADIUS servers
    • TACACS+ login users access authentication
    • RADIUS / TACACS+ users access authentication
    • Guest VLAN assigns clients to a restricted VLAN with limited services
  • Access Control List
    • IP-based Access Control List (ACL)
    • MAC-based Access Control List
  • Source MAC/IP address binding
  • DHCP Snooping to filter un-trusted DHCP messages
  • Dynamic ARP Inspection discards ARP packets with invalid MAC address to IP address binding
  • IP Source Guard prevents IP spoofing attacks
  • IP address access management to prevent unauthorized intruder

 

Management

  • IPv4 and IPv6 dual stack management
  • Switch Management Interfaces
    • Web switch management
    • Telnet Command Line Interface 
    • SNMP v1 and v2c switch management
    • SSHv2, TLSv1.2 and SNMP v3 secure access
  • SNMP Management
    • Four RMON groups (history, statistics, alarms, and events) 
    • SNMP trap for interface Link Up and Link Down notification
  • IPv6 IP Address/NTP/DNS management
  • Built-in Trivial File Transfer Protocol (TFTP) client
  • BOOTP and DHCP for IP address assignment
  • System Maintenance
    • Firmware upload/download via HTTP
    • Reset button for system reboot or reset to factory default
    • Dual Images
  • DHCP Relay and DHCP Option82
  • DHCP Server
  • User Privilege levels control
  • NTP (Network Time Protocol)
  • UPnP
  • Network Diagnostic
    • ICMPv6/ICMPv4 Remote Ping
    • Cable Diagnostic technology provides the mechanism to detect and report potential cabling issues
    • SFP-DDM (Digital Diagnostic Monitor)
  • SMTP, Syslog and SNMP trap remote alarm
  • Local system Log
  • PLANET Smart Discovery Utility for deployment management
  • PLANET NMS system and CloudViewer for deployment management
Hardware Specifications
Copper Ports2 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports
SFP Fiber Ports2 100/1000/2500BASE-X SFP interfaces (Port-3 and Port-4)
RAM128MBytes
Flash Memory64MBytes
Reset Button< 5 sec: System reboot
> 5 sec: Factory default
ESD Protection6KV DC
EnclosureIP30 metal case
InstallationDIN-rail kit and wall-mount kit
ConnectorRemovable 6-pin terminal block for power input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2
AlarmOne relay output for power failure. Alarm relay current carry ability: 1A @ 24V DC
Dimensions (W x D x H)32 x 87 x 135 mm (W x D x H)
Weight390g
Power RequirementsDual 9~48V DC, 24V AC
Power ConsumptionAC Input
Max. 10 watts/24BTU (Ethernet Full Loading)
DC Input
Max. 6.5 watts/24BTU (Ethernet Full Loading)
LED IndicatorSystem:
Power 1 (Green)
Power 2 (Green)
Fault Alarm (Red)
Ring (Green)
Ring Owner (Green)
Per 10/100/1000T RJ45Ports:
1000 LNK/ACT (Green)
10/100 LNK/ACT (Amber)
Per SFP Interface:
10/100 LNK/ACT (Amber)
1G/2.5G LNK/ACT (Green)
Switching
Switch ArchitectureStore-and-Forward
Switch Fabric14Gbps/non-blocking
Throughput (packet per second)10.42Mpps@ 64 bytes packet
Address Table4K entries, automatic source address learning and aging
Shared Data Buffer4Mbits
Flow ControlIEEE 802.3x pause frame for full duplex
Back pressure for half duplex
Jumbo Frame9K bytes
Layer 3 Functions
IP InterfacesMax. 8 VLAN interfaces
Routing TableMax. 32 routing entries
Routing ProtocolsIPv4 software static routing
IPv6 software static routing
Layer 2 Function
Port ConfigurationPort disable/enable
Auto-negotiation 10/100/1000Mbps full and half duplex mode selection
Flow control disable/enable
Power saving mode control
Port StatusDisplay each port’s speed duplex mode, link status, flow control status,
auto negotiation status, trunk status
Port MirroringTX / RX / Both
Many-to-1 monitor
VLANIEEE 802.1Q tag-based VLAN
IEEE 802.1ad Q-in-Q tunneling
Private VLAN Edge (PVE)
MAC-based VLAN
Protocol-based VLAN
VLAN Translation
Voice VLAN
MVR (Multicast VLAN Registration)
GVRP
Up to 4K VLAN groups, out of 4094 VLAN IDs
Link AggregationIEEE 802.3ad LACP/static trunk
Supports 6 trunk groups with 4 ports per trunk group
Spanning Tree ProtocolIEEE 802.1D Spanning Tree Protocol
IEEE 802.1w Rapid Spanning Tree Protocol
IEEE 802.1s Multiple Spanning Tree Protocol
IGMP SnoopingIPv4 IGMP (v1/v2/v3) snooping
IPv4 IGMP querier mode support
Up to 255 multicast groups
MLD SnoopingIPv6 MLD (v1/v2) snooping
IPv6 MLD querier mode support
Up to 255 multicast groups
Bandwidth ControlPer port bandwidth control
Ingress: 500Kb~1000Mbps
Egress: 500Kb~1000Mbps
RINGSupports ERPS, and complies with ITU-T G.8032
Recovery time < 10ms
SynchronizationIEEE 1588v2 PTP(Precision Time Protocol)
Peer-to-peer transparent clock
End-to-end transparent clock
QoSTraffic classification based, strict priority and WRR
8-level priority for switching
Port number
802.1p priority
802.1Q VLAN tag
DSCP/TOS field in IP packet
Security Functions
Access Control ListIP-based ACL/MAC-based ACL
ACL based on:
MAC Address
IP Address
Ethertype
Protocol Type
VLAN ID
DSCP
802.1p Priority
Up to 256 entries
SecurityPort Security
IP source guard
Dynamic ARP inspection
Command line authority control based on user level
AAARADIUS client
TACACS+ client
Network Access ControlIEEE 802.1x port-based network access control
MAC-based authentication
Local/RADIUS authentication
Switch Management
Basic Management InterfacesTelnet; Web browser; SNMP v1, v2c
Secure Management InterfacesSSHv2, TLS v1.2, SNMP v3
System ManagementFirmware upgrade by HTTP protocol through Ethernet network
Configuration upload/download through HTTP
Remote syslog
System log
LLDP protocol
NTP
PLANET Smart Discovery Utility
PLANET CloudViewer app
Event ManagementRemote syslog
Local system log
SMTP
SNMP MIBsRFC 1213 MIB-II
RFC 2863 IF-MIB
RFC 1493 Bridge MIB
RFC 1643 Ethernet MIB
RFC 2863 Interface MIB
RFC 2665 Ether-Like MIB
RFC 2737 Entity MIB
RFC 2819 RMON MIB (Groups 1, 2, 3 and 9)
RFC 2618 RADIUS Client MIB
RFC 3411 SNMP-Frameworks-MIB
IEEE 802.1X PAE
LLDP
MAU-MIB
Standards Conformance
Regulatory ComplianceFCC Part 15 Class A, CE
Stability TestingIEC60068-2-32 (free fall)
IEC60068-2-27 (shock)
IEC60068-2-6 (vibration)
Standards ComplianceIEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX/100BASE-FX
IEEE 802.3z Gigabit SX/LX
IEEE 802.3ab Gigabit 1000T
IEEE 802.3x flow control and back pressure
IEEE 802.3ad port trunk with LACP
IEEE 802.1D Spanning Tree Protocol
IEEE 802.1w Rapid Spanning Tree Protocol
IEEE 802.1s Multiple Spanning Tree Protocol
IEEE 802.1p Class of Service
IEEE 802.1Q VLAN tagging
IEEE 802.1ad Q-in-Q VLAN stacking
IEEE 802.1X Port Authentication Network Control
IEEE 802.1ab LLDP
IEEE 802.3ah OAM
IEEE 1588 PTPv2
RFC 768 UDP
RFC 793 TFTP
RFC 791 IP
RFC 792 ICMP
RFC 2068 HTTP
RFC 1112 IGMP v1
RFC 2236 IGMP v2
RFC 3376 IGMP version 3
RFC 2710 MLD version 1
RFC 3810 MLD version 2
ITU-T G.8032 ERPS Ring
Environment
Operating Temperature-40 ~ 75 degrees C
Storage Temperature-40 ~ 85 degrees C
Humidity5 ~ 95% (non-condensing)

 

Datasheet

DateVersionDescriptionDownload
2024-08-161.0IGT-900-2T2S

 

Firmware

DateVersionDescriptionDownload
2024-08-151.440b240719Function added:
- Added PSTI function.
FW upgrade for PSTIA (Product Security and Telecommunications Infrastructure Act)
*Note: After updating the firmware, you will need to enter the product's MAC code at the first login. Please record the MAC code before proceeding with the update.
2022-12-021.440b220912Bug Fixed -
Authentication request appears twice when logging into the console of the IGS-900-2T2S via SSH (Secure Shell) with the previous firmware version (v1.440b211210). The firmware update with version 1.440b220912 has fixed this issue.

 

Quick Guide

DateVersionDescriptionDownload
2024-08-161.1Added PSTI fuction.
2022-01-141.0Initial release.

 

User's Manual

DateVersionDescriptionDownload
2024-08-151.1Added PSTI function.
2022-03-111.0Initial release.

 

EC Declaration

DateVersionDescriptionDownload
2022-09-271.0EC Declaration.