Cost-effective Solution for RS232/422/485 Serial-to-Industrial Ethernet Application

PLANET ICS-2400T Serial Device Server is specially designed to convert RS232, RS422 or RS485 serial communication to Industrial Fast Ethernet networking so as to extend the network distance efficiently and inexpensively. There are two 10/100BASE-TX RJ45 ports available in the ICS-2400T for your network needs. The ICS-2400T is a time-saving and cost-effective solution for users and system integrators to quickly transform their serial devices into the Ethernet network with no need of replacing the existing serial devices and software system.  

Remote Management 

As the ICS-2400T provides an easy serial-to-Ethernet connectivity and connection to a TCP/IP network, the remote network system can thus be managed efficiently via its Web, telnet and VCOM management interfaces. It supports both application and serial operation modes for alarm or IP address connection, which saves the network administrator’s time in detecting and locating network problems without visual inspection of the cabling and devices.  Multiple connection options are available for large networking environment as well.

 

Stable Performance under Difficult Environments

The ICS-2400T provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curbside traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the ICS-2400T to be placed in almost any difficult environment. 

The ICS-2400T, equipped with compact IP40 standard metal case, allows either DIN-rail or wall mounting for efficient use of cabinet space.  The ICS-2400T also provides an integrated power supply source with a wide range of voltages (12 to 48V DC) ideally suitable for worldwide operation with high availability applications requiring dual or backup power inputs.

 

Dual Power Input for High Availability Network System

The ICS-2400T features a strong dual power input system with wide-ranging voltages (12V~48V DC) incorporated into customer’s automation network to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically to keep powering the ICS-2400T via Power Supply 2 without any break of operation.

 

Effective Alarm Alert for Better Protection

The ICS-2400T comes with a Fault Alarm feature which can alert the users when there is something wrong with the Serial Device Server. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource. The ICS-2400T provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.

 

Digital Input and Digital Output for External Alarm

With digital input and digital output on its front panel, an external alarm can help users via the digital input to detect and log external device status (such as door intrusion detector), and then immediately send an event alarm to the administrator. The digital output can be used to alarm the administrator if the ICS-2400T serial port shows DCD, changed DSR or power failure.

Access Control System – Traditional System Application

Most of the enterprises and government use access control plate and Mifare or RFID to authorize entrance identity. Traditionally, the access control machines use RS232 or RS485 serial interface with their cables connecting to login server. By applying the ICS-2400T, the access control machine is able to extend the network over longer distances via Ethernet interfaces. In addition, the ICS-2400T can be linked to an xDSL router to get the internet access capability so that the access control can be set and monitored over the internet.

 

Process Control

To monitor, configure and manage the robotic conveyer including other production machines, PLC (Programmable Logical Control) is required to drive the above manufacturing process. The ICS-2400T can be set to the TCP Server mode and connected to the PLC.  Thus, the administrator can configure and set command settings through Fast Ethernet intranet to remotely control the PLC, without having to stand by the I/O machine.

Surveillance Motion Control – Pair Connection Mode

Using pair connection mode via the fiber optical patch cord, the ICS-2400T can extend the distance of the deployed devices via RS232, RS422 and RS485 interfaces, making the remote management of these devices from the monitoring center easier and efficient.

Serial Interface

  • Four DB9 interfaces support RS232, 2-wire RS485, 4-wire RS485 and RS422 operation
  • Asynchronous serial data rates up to 921600bps
  • Data mode including VCOM, RFC2217, TCP Server, TCP Client, UDP, Remote Pair and Serial Telnet modes

 

Ethernet Interface

  • 2-port 10/100BASE-TX RJ45 interface with auto MDI/MDI-X function
  • Ethernet ports support Ethernet switch or cascading operation for easy wiring

 

Management

  • IPv4 and IPv6 dual stack management
  • Remote Management Interfaces
  • - IP-based Web management
    - Telnet console management
    - Windows-based VCOM utility supports searching, monitoring and configuration setting
  • IP NTP (Network Time Protocol) and DNS management
  • Standard TCP/IP interface and versatile operation modes
  • Software Protocol supports ARP, ICMP, TCP/IP, UDP, HTTP server, DHCP client, Telnet server/client 
  • Serial Operation mode selected via management interface
  • Pair Connection mode for connecting two serial devices over a network
  • Allows a max. of 4 hosts to be accessed as TCP client mode
  • Firmware upgrade via HTTP protocol
  • Accessible IP security control to prevent illegal users
  • Event notification
  • - Remote Syslog server
    - SNMP trap
    - Built-in buzzer
    - Relay output alarm
    - Digital Output (ICS-2400T)
  • DHCP client for IP address assignment 
  • PLANET Smart Discovery utility automatically finds the client devices on the network

 

Industrial Case and Installation

  • IP40 metal case 
  • DIN-rail and wall-mount designs
  • Redundant power design
  • - 12 to 48V DC, redundant power with polarity reverse protect function
  • Supports 6000 VDC Ethernet ESD protection
  • -40 to 75 degrees C operating temperature
  • Free fall, shock-proof and vibration-proof for industries
  • Supports extensive LED indicators for network diagnosis
  • Reset button for reset to factory default

 

Digital Input and Digital Output

  • 2 Digital Input (DI)
  • 2 Digital Output (DO)
  • Integrate sensors into auto alarm system
  • Transfer alarm to IP network via email and SNMP trap
Serial Interface
Serial Ports4 x DB9 male
Serial StandardsRS232/RS422/4-wire RS485/2-wire RS485
Baud Rate (Data Rate)50bps to 921Kbps
Data Bits5, 6, 7, 8
Parity Type1, 1.5, 2
Stop BitOdd, Even, None, Space, Mark
Flow ControlRTS/CTS and DTR/DSR (RS232 only)
XON/XOFF
SignalsRS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS422: Tx+, Tx-, Rx+, Rx-, GND
4-wire RS485: Tx+, Tx-, Rx+, Rx-, GND
2-wire RS485: Data A (+), Data B (-), GND
Pin Assignment
PinRS232RS422
RS485-4W
RS485-2W
1DCDTxD+--
2RxDTxD---
3TxDRxD-Data-
4DTRRxD+Data+
5GNDGNDGND
6DSR----
7RTS----
8CTS----
9------
Serial Line Protection2KV isolation protection
1.5KV (level 2) surge protection
15KV ESD protection
Ethernet Interface
Ethernet Ports2 x RJ45
Standard10/100BASE-TX
Distance100m
Switch ArchitectureStore-and-Forward
Address Table1K
ESD Protection6KV
Surge Protection2KV
Hardware
InstallationDIN-rail kit and wall-mount ear
EnclosureIP40 metal
Dimensions (W x D x H)50 x 87 x 135 mm
Weight625 g
LED IndicatorsSystem: Power 1, Power 2, Fault, I/O
TP Port: Link/Active
Serial Port: Tx and Rx
Power Requirements12~48V DC, redundant power with polarity reverse protection function
Power ConsumptionFull Loading
12VDC: 0.419A (5.1 watts)
24VDC: 0.227A (5.4 watts)
48VDC: 0.136A (6.5 watts)
ConnectorRemovable 6-pin terminal block for power input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2
DI and DO2 Digital Input (DI):
Level 0: -24V~2.1V (±0.1V)
Level 1: 2.1V~24V (±0.1V)
Input Load to 24V DC, 10mA max.

2 Digital Output (DO):
Open collector to 24V DC, 100mA max.
AlarmProvides one relay output for power failure
Alarm relay current carry ability: 1A @ DC 24V
Reset Button< 5 sec: System reboot
> 5 sec: Factory default
Management
Management InterfacesWeb management
Telnet Console management
Windows-based VCOM Utility management
PLANET Smart Discovery Utility
IP VersionIPv4 and IPv6
Operation ModeTCP Server
TCP Client
UDP Client
Virtual COM
RFC2217
Telnet Server
Pair Connection – Remote (Slave)
Pair Connection – Local (Master)
Virtual COM Utility Platform SupportsWindows Base Only:
Windows XP
Windows Server 2003
Windows 7
Windows Server 2008
Windows 8 (Must install the latest version of WinPcap)
Windows Server 2012 (Must install the latest version of WinPcap)
Windows 10
AlertBuilt-in buzzer and RTC
SecurityAllow max. 4 accessible IP address hosts/ranges
SNMP MIBsRFC1213 MIB-II
RFC1317 RS232-like MIB
Standards Conformances
Regulatory ComplianceFCC Part 15 Class A,
CE Certification Class A
Stability TestingIEC60068-2-32 (Free fall)
IEC60068-2-27 (Shock)
IEC60068-2-6 (Vibration)
StandardsIEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3x flow control and back pressure
RFC 768 UDP
RFC 793 TFTP
RFC 791 IP
RFC 792 ICMP
RFC 854 Telnet
RFC 958 NTP
RFC 1591 DNS (client only)
RFC 1908 SNMPv2c
RFC 2068 HTTP
RFC 2131 DHCP Client
RFC 2732 Format for Literal IPv6 Addresses in URL's
RFC 3315 DHCPv6 Client
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNSv6
RFC 4443 ICMPv6
EIA/TIA RS232/422/485
Regulatory ApprovalRoHS
Environment
Operating Temperature-40 ~ 75 degrees C
Storage Temperature-40 ~ 85 degrees C
Humidity5 ~ 95% (non-condensing)

 

Datasheet

DateVersionDescriptionDownload
2021-08-161.0ICS-2400T

 

Quick Guide

DateVersionDescriptionDownload
2022-12-141.2Add ICS-2100T / ICS-2102TS.
2019-04-261.0Initial release.

 

User's Manual

DateVersionDescriptionDownload
2023-04-211.2Modify contents of user manual.
2021-08-181.2Content update.
2020-07-301.1Add ICS-210xT series.
2019-02-221.0Initial release.

 

Utility

DateVersionDescriptionDownload
2020-12-112011041000_2521_1337_11111. Supports starting as service mode.
2. Supports simplified Chinese
*Note:This utility is only for the ICS-110, ICS-120, ICS-115A, ICS-2100T, ICS-2102T, ICS-2102TS, ICS-2105AT, ICS-2200T, and ICS-2400T and NOT compatible with ICS-100, ICS-105A, ICS-2100, and ICS-2105A.
2019-07-052.18.1219.16001. Support to add Device IP manually.
2. Support to add COM port manually.
3. NOT compatible with ICS-210X series products.

 

EC Declaration

DateVersionDescriptionDownload
2023-12-291.0EC Declaration.